Rosemount 2088 Pressure Transmitter Product Offering
Proven reliability for gage and absolute applications
Available protocols include 4-20 mA HART and 1-5 Vdc HART Low Power
Fully configurable LCD display to display process variable, percent of range, and diagnostic messages
Lightweight, compact design enables easy installation
Choice of Stainless Steel or Alloy C-276 wetted materials
Unlock the value of devices with the Smart Wireless THUM™
Adapter
Gain access to field intelligence and improve quality, safety, availability, operations, and
maintenance costs
Remotely manage devices and monitor health
Enable new wireless measurement points
Utilize existing loop power
Proven, reliable, and innovative DP Level technologies
Connect to virtually any process with a comprehensive offering of process connections, fill fluids,
direct mount or capillary connections and materials
Quantify and optimize total system performance with QZ option
Instrument manifolds – quality, convenient, and easy
Designed and engineered for optimal performance with Rosemount transmitters
Save installation time and money with factory assembly
Offers a variety of styles, materials, and configurations
Power supply effect
Less than ±0.005% of calibrated span per volt change in voltage
at the transmitter terminals.
Mounting position effect
Zero shifts to ±2.5 inH2O (6,22 mbar), which can be zeroed
Span: no effect
Transient protection
Tested in accordance with IEEE C62.41.2-2002,
Location Category B
6 kV crest (0.5 μs - 100 kHz)
3 kA crest (8 x 20 microseconds)
6 kV crest (1.2 x 50 microseconds)
General specifications
Tested to IEC 801-3
Output
Code S: 4–20 mA
Code N: 1-5 Vdc, low power
(Outputs are directly proportional to the input pressure)
Selectable HART
Digital communications based on HART Revision 5 (default) or
Revision 7 (option code HR7) protocol can be selected. The
HART revision can be switched in the field using any HART based
configuration tool or the optional local operator interface (LOI).
Service
Liquid, gas, and vapor applications
Power supply
External power supply required. Transmitter operates on
10.5–42.4 Vdc with no load (5.8-28 V for Low Power). Reverse
polarity protection is standard.
Load Limitations
Reverse polarity protection is standard. Maximum loop
resistance is determined by the power supply voltage as